{"created":"2023-05-15T09:02:52.902990+00:00","id":3767,"links":{},"metadata":{"_buckets":{"deposit":"3bdb6e31-18be-4853-a325-eb68cae05646"},"_deposit":{"created_by":3,"id":"3767","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"3767"},"status":"published"},"_oai":{"id":"oai:hirosaki.repo.nii.ac.jp:00003767","sets":["557:561:653"]},"author_link":["13703","13691","10772","13430","13694","13695","10781","13698","13700","13693","13699","10764","13692","13408","13419"],"item_3_alternative_title_21":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Evaluation of Setup Error and Immobilization Method in the Upper Limbs by Using On-Board Imager"}]},"item_3_alternative_title_22":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"On-Board Imager オ モチイタ セットアップ エラー ナラビニ ジョウシ コテイグ ノ コテイ セイド ノ ケンショウ"}]},"item_3_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-02-28","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2-4","bibliographicPageEnd":"175","bibliographicPageStart":"170","bibliographicVolumeNumber":"64","bibliographic_titles":[{"bibliographic_title":"弘前医学"}]}]},"item_3_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"国立大学法人弘前大学医学部附属病院のOn-Board Imagerによる画像誘導放射線治療を行った症例61例を対象として,照射部位及び上肢固定具毎におけるセットアップエラーを分析し,planning target volume(PTV)-margin を算出した.セットアップエラーの平均値は3mm未満で,臨床的に問題はないと考えられた.TV-marginの最大値は,乳房で5.9mm,前立腺で5.5mm,骨盤腔で6.5mm と算出され,このことよりPTV-marginは最大7mmに設定するのが妥当である.上肢固定具の比較において,セットアップエラーの平均値を比較すると,その差は0.3mmであり,固定精度はほぼ同程度であった.利便性や費用を考慮すると,シェルの使用よりも市販の固定具の導入を検討すべきである.今回,弘前大学医学部附属病院独自のPTV-marginが算出され,今後の治療計画の照射野の基準になると考える.","subitem_description_type":"Abstract"}]},"item_3_description_7":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"弘前医学. 64(2-4), 2014, p.170-175","subitem_description_type":"Other"}]},"item_3_full_name_2":{"attribute_name":"著者(ヨミ)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"13694","nameIdentifierScheme":"WEKO"}],"names":[{"name":"テラシマ, シンゴ"}]},{"nameIdentifiers":[{"nameIdentifier":"13695","nameIdentifierScheme":"WEKO"}],"names":[{"name":"フジモト, ススム"}]},{"nameIdentifiers":[{"nameIdentifier":"10781","nameIdentifierScheme":"WEKO"}],"names":[{"name":"アオキ, マサヒコ"}]},{"nameIdentifiers":[{"nameIdentifier":"13419","nameIdentifierScheme":"WEKO"}],"names":[{"name":"タカイ, ヨシヒロ"}]},{"nameIdentifiers":[{"nameIdentifier":"13698","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ホソカワ, ヨウイチロウ"}]}]},"item_3_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"13699","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"100000267","nameIdentifierScheme":"研究者総覧","nameIdentifierURI":"http://hue2.jm.hirosaki-u.ac.jp/html/100000267_ja.html"}],"names":[{"name":"Terashima, Shingo"}]},{"nameIdentifiers":[{"nameIdentifier":"13700","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Fujimoto, Susumu"}]},{"nameIdentifiers":[{"nameIdentifier":"10772","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"476","nameIdentifierScheme":"研究者総覧","nameIdentifierURI":"http://hue2.jm.hirosaki-u.ac.jp/html/476_ja.html"}],"names":[{"name":"Aoki, Masahiko"}]},{"nameIdentifiers":[{"nameIdentifier":"13408","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Takai, Yoshihiro"}]},{"nameIdentifiers":[{"nameIdentifier":"13703","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"75","nameIdentifierScheme":"研究者総覧","nameIdentifierURI":"http://hue2.jm.hirosaki-u.ac.jp/html/75_ja.html"}],"names":[{"name":"Hosokawa, Yoichiro"}]}]},"item_3_publisher_35":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"弘前大学大学院医学研究科・弘前医学会"}]},"item_3_radio_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_radio_item":"Article"}]},"item_3_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00211444","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0439-1721","subitem_source_identifier_type":"ISSN"}]},"item_3_subject_19":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"492.8","subitem_subject_scheme":"NDC"}]},"item_3_subject_23":{"attribute_name":"NIIサブジェクト","attribute_value_mlt":[{"subitem_subject":"医学","subitem_subject_scheme":"Other"}]},"item_3_text_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"弘前大学大学院保健学研究科医療生命科学領域放射線生命科学分野"},{"subitem_text_value":"市立釧路総合病院放射線科"},{"subitem_text_value":"弘前大学大学院医学研究科放射線科学講座"},{"subitem_text_value":"弘前大学大学院医学研究科放射線科学講座"},{"subitem_text_value":"弘前大学大学院保健学研究科医療生命科学領域放射線生命科学分野"},{"subitem_text_value":"Department of Radiological Life Sciences,Division of Medical Life Sciences, Hirosaki University Graduate School of Health Sciences"},{"subitem_text_value":"Department of Radiology,Kushiro City General Hospital"},{"subitem_text_value":"Department of Radiology and Radiation Oncology,Hirosaki University Graduate School of Medicine"},{"subitem_text_value":"Department of Radiology and Radiation Oncology,Hirosaki University Graduate School of Medicine"},{"subitem_text_value":"Department of Radiological Life Sciences,Division of Medical Life Sciences, Hirosaki University Graduate School of Health Sciences"}]},"item_3_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"寺島, 真悟"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"藤元, 晋"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"青木, 昌彦"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"髙井, 良尋"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"細川, 洋一郎"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-03-13"}],"displaytype":"detail","filename":"HirosakiMedJ_64(2-4)_170.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"HirosakiMedJ_64(2-4)_170.pdf","url":"https://hirosaki.repo.nii.ac.jp/record/3767/files/HirosakiMedJ_64(2-4)_170.pdf"},"version_id":"d1de15d1-e7d2-43b1-90c0-18b39df22400"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"放射線治療","subitem_subject_scheme":"Other"},{"subitem_subject":"セットアップエラー","subitem_subject_scheme":"Other"},{"subitem_subject":"計画標的体積","subitem_subject_scheme":"Other"},{"subitem_subject":"radiation therapy","subitem_subject_scheme":"Other"},{"subitem_subject":"set-up error","subitem_subject_scheme":"Other"},{"subitem_subject":"planning target volume(PTV)","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"On-Board Imager を用いたセットアップエラーならびに上肢固定具の固定精度の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"On-Board Imager を用いたセットアップエラーならびに上肢固定具の固定精度の検証"}]},"item_type_id":"3","owner":"3","path":["653"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-03-28"},"publish_date":"2014-03-28","publish_status":"0","recid":"3767","relation_version_is_last":true,"title":["On-Board Imager を用いたセットアップエラーならびに上肢固定具の固定精度の検証"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-05-15T09:41:54.965261+00:00"}